Industrial Hygienic Drainage Solutions
Sanitary Floor Drain Egypt for Hygienic Industrial Facilities
ShababTec sanitary floor drain systems are stainless steel drainage units developed for production and washdown areas where cleanability, material selection and reliable drainage are important. Available configurations include product-contact parts in stainless steel 304 or 316L, multiple outlet dimensions and a combined air-and-water seal arrangement.
The final material, outlet size, cover configuration and installation detail must be selected according to the process liquid, cleaning chemicals, expected flow, floor construction and project requirements.
- SS304 and SS316L product-contact options
- Internal and external finish stated as Ra 0.6–0.8 μm
- Combined air seal and water seal configuration
- Multiple body and outlet diameter combinations

Definition
What Is a Sanitary Floor Drain?
A sanitary floor drain is an industrial drainage component designed to remove wash water and process-area liquids while allowing practical access for inspection and cleaning.
Unlike a decorative bathroom drain, an industrial sanitary drain must be evaluated as part of the complete facility drainage system. Its body geometry, removable parts, surface condition, outlet connection, seals and integration with the finished floor can all affect cleaning, maintenance and drainage performance.
The word “sanitary” should not be treated as a certificate by itself. The complete installation must be reviewed against the applicable project specification, cleaning procedure, process environment and local engineering requirements.
Applications
Industrial Areas Where Sanitary Floor Drains Are Used
ShababTec floor drains can be specified for hygienic industrial areas in pharmaceutical, food, dairy, beverage and cosmetics facilities, subject to project-specific engineering review.
Pharmaceutical Production
Washdown and production-support areas where stainless steel, cleanability and controlled drainage details are required.
Pharmaceutical solutionsFood, Dairy and Beverage
Processing and cleaning areas exposed to water, food residues, detergents and frequent sanitation procedures.
Food and beverage solutionsCosmetics and Personal Care
Liquid and semi-solid production environments that require compatible construction materials and accessible cleaning.
Cosmetics industry solutionsIndustrial Washdown Areas
Utility rooms, equipment washing zones and wet process areas where outlet capacity and floor integration must be coordinated.
Explore ShababTec servicesProduct Configuration
Available Sanitary Floor Drain Construction
The supplied product information lists stainless steel 304 or 316L for product-contact parts, stainless steel 304 for non-contact parts and an internal and external surface finish of Ra 0.6–0.8 μm.
Material
- Product-contact parts
- Stainless steel 304 or 316L
- Non-contact parts
- Stainless steel 304
Surface Finish
- Internal surface
- Ra 0.6–0.8 μm
- External surface
- Ra 0.6–0.8 μm
Seal Arrangement
Combined air seal and water seal arrangement as stated in the supplied product documentation.
Configuration
Multiple body and outlet combinations are listed. Final dimensions, cover type and connections must be confirmed in the approved drawing.
Selection Process
How to Specify the Right Sanitary Floor Drain
Do not select the drain by top-cover size alone. Start with the liquid, cleaning process, expected flow, solids content, installation depth, outlet route and floor loading.
-
01
Define the process environment
Identify the industry, room function, liquids reaching the drain, temperature range and any product or chemical exposure.
-
02
Review the cleaning chemicals
Provide detergent, disinfectant, acid, alkali and chloride information so the material grade can be reviewed correctly.
-
03
Determine the hydraulic requirement
Estimate normal and peak flow, simultaneous washdown discharge, solids or debris and the downstream pipe capacity.
-
04
Confirm the installation geometry
Check available floor depth, finished floor level, waterproofing, vertical or horizontal outlet requirements and maintenance access.
-
05
Review cleaning and maintenance access
Confirm how the cover, basket or sealing components will be removed, inspected, cleaned and returned to the correct position.
-
06
Approve the final drawing
The issued quotation should identify the grade, dimensions, outlet, cover, finish, included components and installation scope.
Send the project conditions before selecting a model
Include the industry, room, liquid type, cleaning chemicals, approximate flow, outlet direction and required quantity.
Material Selection
SS304 or SS316L Sanitary Floor Drain?
SS304 can be suitable for many general hygienic applications, while SS316L is commonly reviewed for more corrosive product or cleaning conditions. The correct grade depends on the actual exposure and should not be chosen from the industry name alone.
| Selection Point | SS304 | SS316L |
|---|---|---|
| Typical discussion | General hygienic and non-contact applications | Product-contact or more demanding corrosive exposure |
| Chloride resistance | Lower than 316L in many chloride-containing conditions | Usually higher due to molybdenum content |
| Cleaning chemicals | Must be checked against chemical concentration, temperature, contact time and cleaning frequency. | |
| Final decision | Confirm through project material review and the approved technical quotation. | |
This comparison is a specification guide, not a corrosion guarantee. Some environments may require a different alloy or operating control.
Technical Data
Sanitary Floor Drain Dimensions
The supplied dimension sheet identifies size combinations using overall flange diameter A, body diameter B, total height H and outlet diameter C. All dimensions below require confirmation against the latest drawing.

| Listed Size | A | B | H | C |
|---|---|---|---|---|
| 108 × 38 | 140 | 108 | 140 | 38 |
| 108 × 51 | 140 | 108 | 140 | 51 |
| 133 × 51 | 160 | 133 | 150 | 51 |
| 133 × 63 | 160 | 133 | 150 | 63 |
| 159 × 76 | 185 | 159 | 155 | 76 |
| 159 × 102 | 185 | 159 | 155 | 102 |
| 219 × 102 | 230 | 219 | 155 | 102 |
| 219 × 159 | 230 | 219 | 155 | 159 |
| 273 × 219 | 320 | 273 | 160 | 219 |
Installation and Maintenance
Installation and Cleaning Considerations
Drain performance depends on correct integration with the floor, wastewater pipe, waterproofing and cleaning procedure—not on the drain body alone.
Before Installation
- Approve the location and finished floor elevation.
- Coordinate floor falls toward the drain.
- Confirm the available installation depth.
- Check the outlet direction and pipe diameter.
- Review waterproofing and floor-finish interfaces.
- Confirm expected traffic and cover loading.
During Installation
- Protect finished stainless surfaces from contamination.
- Keep the drain level coordinated with the finished floor.
- Avoid unsealed gaps around the drain body.
- Verify pipe alignment before final closing.
- Maintain access to removable components.
- Inspect fabricated or welded connections.
Cleaning and Inspection
- Remove and clean accessible covers and internal components.
- Remove accumulated solids before they restrict flow.
- Inspect water-seal and sealing components.
- Use chemicals compatible with the selected stainless grade.
- Avoid tools that scratch or contaminate the surface.
- Record inspection frequency in the facility cleaning SOP.
Where welded stainless connections are part of the project, coordinate the work with the orbital welding service and the approved fabrication procedure.
Commercial Information
What Affects Sanitary Floor Drain Price in Egypt?
A reliable price requires a defined configuration. Publishing one generic price before confirming the material and dimensions can produce an inaccurate comparison.
FAQ
Frequently Asked Questions
What is the difference between a sanitary and ordinary floor drain?
An ordinary drain is often selected mainly by size and appearance. A sanitary industrial drain must also be reviewed for cleanability, material compatibility, removable components, surface condition, sealing, floor integration and the operating environment.
Is SS316L always better than SS304?
No. SS316L generally offers improved resistance in many chloride-containing or corrosive environments, but the final choice depends on the exact liquid, cleaning chemicals, concentration, temperature and exposure time.
Can the drain be used in pharmaceutical facilities?
It can be evaluated for pharmaceutical production and support areas. Acceptance depends on the project specification, installation detail, material documentation, cleaning procedure and any required validation.
What does the double-seal design do?
The supplied product information describes a combined air seal and water seal. Its practical performance depends on correct assembly, installation, water-seal condition, cleaning and maintenance.
How do I choose the correct outlet size?
Review peak washdown flow, simultaneous discharge, solids content, downstream pipe capacity, available depth and outlet direction. The top-cover size alone is not enough.
Can ShababTec manufacture a custom size?
ShababTec provides custom stainless steel fabrication services. The requested dimensions and configuration must be technically reviewed before availability or manufacturability is confirmed.
How often should the drain be cleaned?
Frequency should be defined by the facility’s hygiene risk, wastewater type, solids load and sanitation program. High-soil or frequent-washdown areas normally require more frequent inspection.
Why is there no fixed online price?
Material grade, dimensions, finish, cover design, quantity, documentation and installation scope can change the quotation. A technical request produces a more accurate commercial comparison.
